Building
This object has two purposes. First, it can be utilized to group
Space
objects together for metering. Also, there are some
physical aspects of the the building that can be calculated from
some parameters of the building. For example, the Infiltrations
can be estimated from the number of storeys
and the ShelterClass
(check docs for those).
Examples
.spl
Building {
name: "Main Building",
shelter_class: "Urban"
}
.json
{
"name": "Main Building",
"shelter_class": "Urban"
}
Full Specification
Building {
name : string,
n_storeys : int, // optional,
shelter_class : ShelterClass, // optional,
stack_coefficient : number, // optional,
wind_coefficient : number, // optional,
}
name
The name of the Building
n_storeys (optional)
The number of storeys of this building.
This value use used by the AirFlow
module when a Space
associated
to this Building
has been assigned an EffectiveAirLeakageArea
infiltration. This value is required for calculating the Stack
Coefficient () and the Wind Coefficient () of the
EffectiveAirLeakageArea
infiltration. and can be inputed
directly by assigning values to the stack_coefficient
and
wind_coefficient
fields, in which case the n_storeys
field will
be ignored.
shelter_class (optional)
The ShelterClass
of this building.
This value use used by the AirFlow
module when a Space
associated
to this Building
has been assigned an EffectiveAirLeakageArea
infiltration. This value is required for calculating the Wind
Coefficient () of the
EffectiveAirLeakageArea
infiltration. can be inputed
directly by assigning values to the wind_coefficient
field, in
which case the shelter_class
field will be ignored.
stack_coefficient (optional)
The stack coefficient of this building, used for
calculating infiltrations in Spaces
that utilize the EffectiveAirLeakageArea
infiltration option.
If not given, the number of storeys will be used for getting this values (based on EnergyPlus' Engineering Reference).
Note: The
EffectiveAirLeakageArea
object is appropriate for buildings of 3 storeys or less.
wind_coefficient (optional)
The wind coefficient of this building, used for
calculating infiltrations in Spaces
that utilize the EffectiveAirLeakageArea
infiltration option.
If not given, the number of storeys will be used for getting this values (based on EnergyPlus' Engineering Reference).
Note: The
EffectiveAirLeakageArea
object is appropriate for buildings of 3 storeys or less.